Advanced NDT Services

Phased Array

UT and TOFD

Examine suitable welds and components with advanced ultrasonic techniques that help locate, characterize and size internal discontinuities without cutting the part.

Inspection Snapshot

A clear picture of internal quality

Phased Array UT

Multiple beam angles for targeted weld examination.

Time of Flight Diffraction

Diffracted signals support through-wall flaw sizing.

Inspection Records

Traceable findings linked to the examined component.

Discuss your inspection

Certified Personnel

Qualified NDT professionals

Fast Turnaround

Responsive scheduling

Modern Equipment

Calibrated UT instruments

Detailed Reports

Clear inspection findings

Phased Array UT and TOFD

Component preservation

Examine internal integrity without destructive sectioning. Local surface preparation and couplant may be required.

accent line What are PAUT and TOFD

Two ultrasonic approaches for weld examination

PAUT uses an array of ultrasonic elements and controlled timing to steer and focus sound beams. TOFD uses separate transmitting and receiving probes and the arrival times of signals diffracted at discontinuity tips. Used individually or together, these techniques can improve examination coverage and flaw assessment. TOFD has near-surface and back-wall limitations, so supplementary pulse-echo or surface examination may be necessary.

Weld examination

Flaw location

Through-wall sizing

Repair verification

Recorded scans

Component evaluation

--------- Our Process ---------

A defined scan plan from setup to report

Scope Review

Review the weld profile, material, thickness, drawings, access and applicable acceptance criteria. Confirm whether PAUT, TOFD or a combined examination is appropriate.

Arrow

Scan Plan and Calibration

Establish beam coverage, probe positions and scan paths. Perform the required calibration and sensitivity checks using suitable reference blocks.

Arrow

Systematic Examination

Acquire and review data using the agreed scanning arrangement. Encoded recording and supplementary examinations are included when specified and technically suitable.

Arrow

Evaluation and Report

Assess relevant indications against the governing criteria. Document locations, reported dimensions, coverage and limitations, together with the agreed data deliverables.

--------- Inspection capabilities ---------

Advanced ultrasonic examination for suitable components

RT supports fabrication quality control, repair verification and targeted investigation of suitable industrial components. Examination feasibility depends on material, thickness, geometry and access.

Pipe and Pipeline Welds

Examine suitable butt welds with scan plans tailored to diameter, wall thickness and weld preparation.

Pressure Vessel Welds

Assess suitable shell and seam welds, with additional techniques where geometry restricts coverage.

Structural Welds

Examine suitable structural steel joints where the governing code and project specification permit the selected technique.

Flaw Sizing

Use appropriate pulse-echo and TOFD information to assess discontinuity position and dimensions within the demonstrated capability of the examination.

Repair Verification

Re-examine repaired areas and adjacent required coverage to document the condition after repair.

Recorded Baseline Examinations

Establish traceable scan records for defined locations when encoded acquisition and data retention are included in the scope.

--------- Discontinuities and Findings ---------

What PAUT and TOFD can detect

Depending on orientation, size, material and examination setup, relevant indications may include

Internal cracks

Lack of sidewall

Inter-run fusion

Incomplete penetration

Slag

Selected voids

Repair-related discontinuities

Porosity

Other inclusions

Guarantees detection

--------- Codes & standards ---------

Inspection aligned with your requirements

The applicable code, edition, examination coverage and acceptance criteria are established during scope review. Depending on the component and contract, relevant documents may include:

ASME Section V Article 4

Ultrasonic examination requirements, including applicable technique provisions.

ASTM E2700

Contact ultrasonic testing of welds using phased arrays.

ASTM E2373/E2373M

Use of the TOFD technique.

ASME B31.1 and B31.3

Applicable power and process piping requirements.

API 1104

Pipeline welding and examination where applicable.

AWS D1.1 and CSA W59

Applicable structural weld examination requirements.

--------- Industries served ---------

Supporting quality and asset integrity

accent line

What our clients say

accent line
Posted on Google Google
Paul Herman profile picture
Paul Herman
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Thank you for the quick service and the complete report. Best wishes Paul Herman Firwin Corp
Posted on Google Google
Jon Himelfarb profile picture
Jon Himelfarb
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Great service, above and beyond what was asked for or expected. CMH Metlabs expedited their internal processes to meet an urgent request and helped us meet our deadlines. 100% would recommend them.
Posted on Google Google
Mark Nowakowski profile picture
Mark Nowakowski
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Thank you CMH METLABS for your attention, professionalism and responsive communication. This includes your extra follow-up to confirm the lab test results. We were able to continue our business with minimal delay thanks to your efforts!
Posted on Google Google
George Berton profile picture
George Berton
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Very co operative with information and timing.
Posted on Google Google
ahmadreza asefi profile picture
ahmadreza asefi
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
The professional team, the good testing equipment, the short turnaround time, and the comprehensive reporting have all made us extremely satisfied with this laboratory. We will certainly return to them for future testing needs.
Posted on Google Google
Etienne Fortier profile picture
Etienne Fortier
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Submitted metal sampled for testing, obtained test results promptly and professionally. Highly Recommended.
Posted on Google Google
Sanjay Sharma profile picture
Sanjay Sharma
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
Birla Carbon Hamilton worked with CMH for testing their boiler tube . CMH Metlabs issued a report for their testing. The report was good and covered all technical requirements. We will work with them in future.
Posted on Google Google
Don Webster profile picture
Don Webster
Google star 1Google star 2Google star 3Google star 4Google star 5Trustindex verifies that the original source of the review is Google.
CMH Metlabs did a number of chemical analysis for us over the last few weeks. The prices are good and the turn-around time was excellent. We needed some clarity on the results from the tests. The technical people at CMH responded quicky and our questions were answered. We discovered a couple of typos in the reports but it did not affect the over all accuracy of the report. We are looking forward to continuing our analyses with CMH.

Frequently asked questions

Answers before you schedule

How do PAUT and TOFD differ?
PAUT steers and focuses sound beams to examine a defined volume. TOFD uses diffracted signals to support discontinuity detection and sizing. Their strengths are complementary, but a combined examination is not necessary for every job.
Sometimes, where the governing code, demonstrated procedure and required approvals permit it. Substitution must be agreed before testing; it is not automatic.
PAUT can often work from one scanning side, depending on geometry. Typical TOFD arrangements place probes on opposite sides of the weld on the same accessible surface. Access is assessed during planning.

The quotation should define whether encoded acquisition, native data, images and long-term retention are included. A written examination report is distinct from the underlying scan data.

Site examination may be suitable when access, surface preparation, temperature and safety arrangements permit. Equipment and technique availability are confirmed for the project.

--------- Need an inspection? ---------

Plan an examination around your weld geometry

Send your drawings, component details and acceptance requirements for an assessment of the appropriate radiographic examination approach.

accent line Need an Inspection Contact CMH Metlabs

Plan your inspection

Share your project scope so we can confirm method suitability, availability, access and reporting arrangements.

Tell us about your job

Fields marked * are required. We reply within one business day.

By submitting this form, you agree to be contacted about your inspection request.